Atec Tektronix-VM100-VM101 Manual do Utilizador Página 2

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 8
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 1
Appendix A: Specifications
A–2
VM100 & VM101 User Manual
Electrical Specifications
Table A–1: Input signal requirements–VIDEO INPUT
Category
Description
Maximum Operating Voltage REQ: –1.8 V to +2.2 V
Absolute Maximum Input Voltage REQ: –8.5 V to +8.5 V
Minimum Operating Voltage REQ: 1 Vp-p video signal
RI: Typically operates with a 1 Vp-p
input, +1 dB or –6 dB
DC Input Impedance REQ: 20 KW
RI: DC coupling
Return Loss REQ: >40 dB to 6 MHz
RI: DC coupling
Table A–2: Input signal requirements–EXT REF
Category
Description
Absolute Maximum Input Voltage REQ: –8.5 V to +8.5 V
Minimum Operating Voltage REQ: 1 Vp-p video signal
RI: Typically operates with a 1 Vp-p
input, +1 dB or –6 dB
DC Input Impedance REQ: 20 KW
Return Loss REQ: >40 dB to 6 MHz
Video INPUT / EXT REF
Crosstalk REQ: >70 dB to 6 MHz
Loop-through Isolation RI: >70 dB (typical)
Vista de página 1
1 2 3 4 5 6 7 8

Comentários a estes Manuais

Sem comentários